Translational Sensory & Circadian Neuroscience Unit (MPS/TUM/TUMCREATE)

About this directory

Scope, sources and curation methods for the light logger validation directory.

Literature checked 10 November 2026 · 28 studies · 29 device entries · 26 peer reviewed · 2 preprints · 0 conference paper

Reading the directory

Each square represents one validation study for that device. Orange hatching marks documented developer involvement. The Device outputs columns show confirmed photopic illuminance and melanopic EDI features. Separate Examined in studies columns show whether the listed studies test photopic illuminance, melanopic EDI or angle dependence. Output checks remain fixed when filtering; examination checks follow the matching studies. Counts are not accuracy ratings.

Manufacturers and research developers group related models. Results remain specific to each tested model. “Commercial model” and “Research device” describe the instruments in the cited literature, rather than current purchasing availability.

Output capability and validation are stored separately, with literature sources. A dash means capability has not been established in the inspected sources. Checked independent authorship is noted in study details; unhighlighted squares do not imply independence.

Scope

This directory includes primary studies with extracted direct tests of photopic illuminance, melanopic EDI or angle dependence. Indoor/outdoor and light-source classification papers are excluded unless the paper separately tests one of those three measurements. Placement-only, spectral-only, dose-only and other-endpoint papers are outside this scope. The expanded search is documented below. It is not an exhaustive systematic review: some known candidates still need extraction, and the search can miss relevant work.

Development papers are included when they report measurement tests. Each entry states the evidence type, reference, source access and limits. Inclusion does not certify a device. Reference comparisons, between-device agreement, repeatability and wearing-position studies are labelled separately; they do not provide interchangeable evidence of absolute accuracy.

Sources are research publications and explicitly labelled preprints. Manufacturer specifications and marketing claims are not used as validation evidence. Studies concerned only with sleep, activity, or physiological outcomes do not establish the accuracy of a device’s light sensor and are outside this collection’s measurement scope.

On 10 November 2026, three Europe PMC queries returned 751 records, or 733 unique database accessions. A title prefilter retained 361 titles for inspection. Selected candidates were then checked against primary abstracts or full texts. Named-device searches, publisher and institutional records, and backward citation checking supplemented these queries.

The directory contains 28 papers. 5 currently rely on abstracts; 1 uses a partial full-text passage. The included-paper count is not the number of search hits screened, and does not imply exhaustive coverage.

Exact database queries and counts

391 records, all retrieved. Saved response

TITLE_ABS:((Actiwatch OR ActTrust OR GENEActiv OR MotionWatch OR HOBO OR ActiGraph) AND (light OR illuminance OR photometric) AND (validat* OR calibrat* OR accuracy OR spectral OR agreement OR characteri*)) AND FIRST_PDATE:[1900-01-01 TO 2026-11-10]

306 records, all retrieved. Saved response

TITLE:((light OR illuminance OR photometric OR melanopic) AND (dosimeter OR logger OR wearable OR wrist OR sensor OR monitor)) AND TITLE_ABS:(validat* OR calibrat* OR accuracy OR characteri*) AND FIRST_PDATE:[1900-01-01 TO 2026-11-10]

54 records, all retrieved. Saved response

TITLE_ABS:(Clouclip OR MyLyt OR Daysimeter OR Spectrace OR SpectraWear OR ActLumus OR OcuWEAR OR "LYS Button" OR (Kronowise AND light)) AND FIRST_PDATE:[1900-01-01 TO 2026-11-10]

Europe PMC includes PubMed/MEDLINE and indexed preprints. Search results were deduplicated by database source and accession; the included inventory has unique DOIs. The title prefilter, per-title dispositions and source-check decisions are available below. Records omitted by that prefilter were not manually screened. Three broader pilot searches were capped at 1,000 results each and are excluded from these counts.

Citation checking used the V3 framework, a 2025 light-device survey, the myopia light-meter review, and references in primary papers. Reviews helped identify sources; their device specifications were not treated as validation results.

Limitations include English search terms, the title prefilter, no subscription-database search, indexing delays, incomplete access to older papers, and no independent second screening. Theses and conference abstracts have not been comprehensively assessed. A missing entry does not mean that a device has no validation evidence.

Search audit (JSON) · Title triage (CSV) · Source decisions (CSV)

Other candidates, unresolved papers and scope decisions

Read et al. (2014). Light exposure and physical activity in myopic and emmetropic children ↗

Awaiting full-text check. Application paper may contain device calibration checks; abstract does not resolve whether it adds original performance data.

Source checked: Abstract / citation chain

Schmid et al. (2013). Assessment of daily light and ultraviolet exposure in young adults ↗

Awaiting full-text check. HOBO application; determine whether original calibration or classifier testing is reported.

Source checked: Citation / abstract

Aarts et al. (2020). Can Special Light Glasses Reduce Sleepiness and Improve Sleep of Nightshift Workers? ↗

Awaiting supplement check. LightWatcher calibration supplement may add relevant sensor tests; treatment outcome findings alone are outside scope.

Source checked: Citation chain / supplement description

Huss et al. (2019). Shedding Some Light in the Dark ↗

Awaiting calibration extraction. Main comparison evaluates satellite estimates. Determine whether LightWatcher stability/calibration data justify a separate hardware record.

Source checked: Primary study description / indexed passages

Gourraud et al. (2024). Instrumented eyewear with regular design ↗

Awaiting full-text check. Proceedings report of ocular visible-light sensing; quantitative performance and reference instrument not yet extracted.

Source checked: Publisher metadata

Xu et al. (2026). Validation of a Multimodal Wearable Device for Assessing Environmental and Behavioral Risk Factors of Myopia in Children and Adolescents ↗

Awaiting full-text check. Abstract validates activity and sleep components and describes environmental spectra; it does not establish an independent light-measurement reference test.

Source checked: PubMed abstract

Yoshimura et al. (online 2020; issue 2022). Relationship between Indoor Daytime Light Exposure and Circadian Phase Response under Laboratory Free-Living Conditions ↗

Awaiting full-text check. Check for original position or reference-instrument comparison before assigning sensor-validation endpoints.

Source checked: Citation chain

Verkicharla et al. (2017). Development of the FitSight Fitness Tracker to Increase Time Outdoors to Prevent Myopia ↗

Limited measurement report. Results state that readings were of the same order of magnitude as an in-house meter, but give no quantitative accuracy test or reference model. Usability and wear-time outcomes are not light-sensor validation.

Source checked: Full text: Methods and Results

Alvarez & Wildsoet (2013). Quantifying light exposure patterns in young adult students ↗

Application / no extracted sensor validation. HOBO exposure profiles and questionnaire/environmental context; no independent quantitative sensor calibration identified in the inspected text.

Source checked: Full text

Dickey AK, Berkovich J, Leaf RK, Jiang PY, Lopez-Galmiche G, Rebeiz L, Wheeden K, Kochevar I, Savage W, Zhao S, Campisi E, Heo SY, Trueb J, LaRochelle EPM, Rogers J, Banks A, Chang JK. (2024). Observational pilot study of multi-wavelength wearable light dosimetry for erythropoietic protoporphyria. ↗

Clinical association / related application. Clinical symptom association is not independent light-sensor accuracy. Hardware platform development is represented by Heo and Kwon.

Source checked: Full text / abstract

Heil DP, Mathis SR. (2002). Characterizing free-living light exposure using a wrist-worn light monitor. ↗

Application / abstract inconclusive. Accessible abstract describes occupational exposure patterns without an independent light-measurement validation. Full text could contain additional technical checks.

Source checked: PubMed abstract

Ulaganathan et al. (2017). Measurement Duration and Frequency Impact Objective Light Exposure Measures ↗

Related sampling methods. Sampling-duration reliability concerns exposure summaries; not a standalone absolute sensor-accuracy test.

Source checked: Citation / abstract

de Vries et al. (2026). Light exposure measurement and body geometry ↗

Related simulation methods. Uses body geometry and simulated illumination; no measured wearable-hardware validation.

Source checked: Full text

de Vries et al. (2026). Hybrid light-exposure measurement framework ↗

Related simulation methods. Body scans and simulated placement/occlusion effects; not a separate empirical sensor-validation dataset.

Source checked: Full text

Patterson Gentile C, Thomas A, Shah R, Marquez De Prado B, Raj N, Szperka CL, Aguirre GK. (2026). Evaluating chest-worn light logger adherence: development and application of a wear/non-wear model. ↗

Related adherence methods. Validates nonwear detection rather than light-measurement accuracy. Preprint 10.1101/2025.09.29.25336898 is not counted again.

Source checked: Indexed journal record / abstract

Zhang Y, Wijeratne LOH, Talebi S, Lary DJ. (2021). Machine Learning for Light Sensor Calibration. ↗

Outside wearable scope. Stationary environmental light sensor network rather than wearable personal dosimetry.

Source checked: Full text

Cole et al. (1990). Ambulatory monitoring of light exposure: comparison of measurements at forehead and wrist

Limited report; not yet extracted. Sleep Research 19:364 conference abstract found through citations; primary abstract and device details not retrieved.

Source checked: Secondary citation only

Deuring et al. (2026). Wearable Light Dosimeter with RGB Sensors: A Practical Approach to Determine Melanopic EDI for Daylight Measures ↗

Limited report; not yet extracted. Conference abstract within Clocks & Sleep 8(1):2; ActTrust2. Not a full validation paper.

Source checked: Conference abstract listing

Nishanth et al. (2022). Accurate Measurement of Outdoor Activities in Children with Myopia: Development of an Affordable Wearable Device

Limited report; not yet extracted. IOVS 63(7):2144–A0172 meeting abstract; determine overlap with subsequent full papers before counting independently.

Source checked: Citation chain

Hubalek (2007). Light measurement / LuxBlick doctoral thesis

Thesis not yet assessed. Original thesis may contain validation data; eligibility and overlap with journal publications remain unresolved.

Source checked: Review bibliography

Moafa (2019). Quantifying Risk Factors for Myopia: Instrument Validation and Establishing Dosage for Light Intensity and Duration

Thesis not yet assessed. Thesis may contain additional validation experiments; full-text extraction and publication-overlap assessment remain open.

Source checked: Review bibliography

Philips (2008). Characterization of Light Sensor Performance for Three Models of Actiwatch

Manufacturer material excluded. Manufacturer white paper, not an indexed research publication in the present literature-only collection.

Source checked: Citation chain

Okudaira, Kripke & Webster (1983). Naturalistic studies of human light exposure ↗

Excluded by curator. Removed from the directory at the curator’s request on 10 November 2026.

Source checked: Abstract

Liu et al. (2026). From Spectra to Digital Phenotypes: Wearable Multispectral Sensing for Precision Light and Green Space Exposure ↗

Outside narrowed scope. No extracted direct test of photopic illuminance, melanopic EDI or angle dependence. Classification-only and other-endpoint records are excluded from this directory.

Source checked: Abstract

Gibaldi et al. (2024). A Child-Friendly Wearable Device for Quantifying Environmental Risk Factors for Myopia ↗

Outside narrowed scope. No extracted direct test of photopic illuminance, melanopic EDI or angle dependence. Classification-only and other-endpoint records are excluded from this directory.

Source checked: Full text

Shneor, Gordon-Shaag, Doron, Benoit & Ostrin (2024). Utility of the Actiwatch Spectrum Plus for detecting the outdoor environment and physical activity in children ↗

Outside narrowed scope. No extracted direct test of photopic illuminance, melanopic EDI or angle dependence. Classification-only and other-endpoint records are excluded from this directory.

Source checked: Full text

Rhudy et al. (2020). Wearable light data logger for studying physiological and psychological effects of light data ↗

Outside narrowed scope. No extracted direct test of photopic illuminance, melanopic EDI or angle dependence. Classification-only and other-endpoint records are excluded from this directory.

Source checked: Full text

Dumortier et al. (2019). One year of use of a light dosimeter ↗

Outside narrowed scope. No extracted direct test of photopic illuminance, melanopic EDI or angle dependence. Classification-only and other-endpoint records are excluded from this directory.

Source checked: Full text

Kwon et al. (2019). Miniaturized, light-adaptive, wireless dosimeters autonomously monitor exposure to electromagnetic radiation ↗

Outside narrowed scope. No extracted direct test of photopic illuminance, melanopic EDI or angle dependence. Classification-only and other-endpoint records are excluded from this directory.

Source checked: Full text

Ye et al. (2019). Discrimination of indoor versus outdoor environmental state with machine learning algorithms in myopia observational studies ↗

Outside narrowed scope. No extracted direct test of photopic illuminance, melanopic EDI or angle dependence. Classification-only and other-endpoint records are excluded from this directory.

Source checked: Full text

Heo et al. (2018). Wireless, battery-free, flexible, miniaturized dosimeters monitor exposure to solar radiation and to light for phototherapy ↗

Outside narrowed scope. No extracted direct test of photopic illuminance, melanopic EDI or angle dependence. Classification-only and other-endpoint records are excluded from this directory.

Source checked: Full text

Cao & Barrionuevo (2015). Estimating photoreceptor excitations from spectral outputs of a personal light exposure measurement device ↗

Outside narrowed scope. No extracted direct test of photopic illuminance, melanopic EDI or angle dependence. Classification-only and other-endpoint records are excluded from this directory.

Source checked: Full text

Flynn et al. (2014). Detecting indoor and outdoor environments using the ActiGraph GT3X+ light sensor in children ↗

Outside narrowed scope. No extracted direct test of photopic illuminance, melanopic EDI or angle dependence. Classification-only and other-endpoint records are excluded from this directory.

Source checked: Abstract

Dharani et al. (2012). Comparison of measurements of time outdoors and light levels as risk factors for myopia in young Singapore children ↗

Outside narrowed scope. No extracted direct test of photopic illuminance, melanopic EDI or angle dependence. Classification-only and other-endpoint records are excluded from this directory.

Source checked: Abstract

Duncan et al. (1995). The development of personal dosimeters for use in the visible and ultraviolet wavelengths regions. The Salisbury Eye Evaluation Team. ↗

Outside narrowed scope. No extracted direct test of photopic illuminance, melanopic EDI or angle dependence. Classification-only and other-endpoint records are excluded from this directory.

Source checked: Abstract

Aarts et al. (2017). Performance of personally worn dosimeters to study non-image forming effects of light: Assessment methods ↗

Excluded by curator. Anonymised device models cannot support lookup of identifiable light loggers; removed at the curator’s request.

Source checked: Full text

Zauner et al. (2026). Sensor placement causes outcome-dependent bias in ambulatory light-exposure estimates ↗

Outside narrowed scope. Placement-only study excluded at the curator’s request; direct device-performance studies remain.

Source checked: Full text

Wen et al. (2023). Effect of mount location on the quantification of light intensity in myopia study ↗

Outside narrowed scope. Placement-only study excluded at the curator’s request; direct device-performance studies remain.

Source checked: Full text

Jardim et al. (2011). Validating the use of wrist-level light monitoring for in-hospital circadian studies ↗

Outside narrowed scope. Placement-only study excluded at the curator’s request; direct device-performance studies remain.

Source checked: Abstract

Higgins et al. (2007). Light measurement in the hospital: A comparison of two methods ↗

Excluded by curator. Unnamed hospital logger removed at the curator’s request; its model cannot be identified.

Source checked: Abstract

How to read an entry

Device names. LYS and LYS Button are one device entry; the name used in each paper is retained where relevant. Other unresolved versions remain explicitly labelled. “Device entries” includes prototypes, unnamed models and one group of seven anonymised dosimeters; it is not a count of distinct commercial models.

Publication images. Journal and preprint-server marks identify sources. Where a journal-specific asset was unavailable, a publisher logo or the journal’s name is used. Covers identify the venue, not necessarily the paper’s issue. Device images are not shown.

Curation and updates

Records contain a citation, persistent source link, tested device names, measurement categories, setting, reference, protocol summary, findings, limitations, and a locator for the supporting source passage, table or figure. Device-specific endpoint mappings prevent tests reported for one model from being assigned to every model in the same paper. Summaries are brief paraphrases; consult the original paper for numerical results, uncertainty, and complete methods. A paper may include several devices, so study counts and device counts are different units.

Publication years. Years follow the checked research records. Some use journal issue year and some online-first year; discrepancies are identified in each record’s notes. Publication year is not the date of testing.

Use Submit a validation on the directory to suggest a paper. A curator should check the source, model, methods, review status and conclusions before adding it. Submissions are not added automatically. New versions of a preprint should update the existing record rather than be counted as independent studies.

Reproduce and reuse

The website and this notebook read the same versioned JSON inventory. Rendering the directory notebook rebuilds the interface and downloadable records; this notebook regenerates the provenance inventory below. The build does not query websites or change the literature records. Search and filters run in the visitor’s browser.

The CSV preserves the study summaries and device-specific endpoint mappings. The BibTeX export contains partial citation metadata: title, DOI, URL and the indexed year. Abbreviated display authors are preserved in the note field rather than represented as a complete author list. Resolve the DOI for complete author, journal and publication-date metadata before using the export in a manuscript.

Download the study table (CSV) · Download citations (BibTeX) · Download this notebook

Study inventory

Gemici et al. · 2026 · Preprint

Scene-based field validation of wearable light loggers ↗

Journal / server
arXiv
Devices
ActTrust2; ActLumus
Measurements
Illuminance; Melanopic EDI
Device-specific coverage
ActTrust2: Illuminance | ActLumus: Illuminance, Melanopic EDI
Setting
Field
Evidence type
Reference comparison
Reference
JETI Spectraval 1501 in Tübingen; Konica Minolta CL-500A in Izmir.
Protocol
Fixed tripod rig sampled 433 indoor/outdoor scenes across daylight, artificial and mixed lighting in Tübingen and Izmir. Bootstrap resampling assessed sampling requirements.
Reported findings
High association with reference measurements coexisted with systematic underestimation. Bias depended on the lighting condition and scene characteristics. Performance estimates stabilized at approximately 100 sampled scenes in this dataset.
Limits of interpretation
Preprint. Tripod measurements do not establish continuous on-body accuracy. Only one ActTrust2 unit and two ActLumus units were tested, with one ActLumus at each site.
Source inspected
Full text
Evidence location
PDF pp. 6–7: Measurement setup; pp. 11–12: Results; Figure 2: A ActLumus mEDI, B ActLumus illuminance, C ActTrust2 illuminance.
Curation note
arXiv v1, 16 June 2026. Both devices measured photopic illuminance; only ActLumus measured melanopic EDI. The same ActTrust2 unit was used at both sites.

Kore et al. · 2026 · Peer reviewed

Evaluation of wearable light dosimeters for circadian lighting: spectral, spatial, photometric, melanopic, and thermal performance ↗

Journal / server
npj Biological Timing and Sleep
Devices
LYS Button; Blue Iris Speck v1.0; Actiwatch Spectrum Plus
Measurements
Angular response; Illuminance; Melanopic EDI
Device-specific coverage
LYS Button: Illuminance, Melanopic EDI, Angular response | Blue Iris Speck v1.0: Illuminance, Melanopic EDI, Angular response | Actiwatch Spectrum Plus: Illuminance, Angular response
Setting
Laboratory + field
Evidence type
Characterisation
Reference
Calibrated Gigahertz-Optik BTS256 spectroradiometer; cosine-law angular benchmark.
Protocol
Three units per model tested under controlled LEDs (0–570 lx) and partly cloudy daylight (42,000–78,000 lx), with separate angular and temperature tests.
Reported findings
Speck showed the strongest overall measurement agreement in this comparison. LYS Button overestimated low-light melanopic EDI. Actiwatch had substantial photometric variability. All models showed difficulties under high daylight levels.
Limits of interpretation
Three units per type; one short daylight session; spectral reconstruction evaluated for only one Speck; no on-body position or occlusion testing. Daylight variability limits interpretation as a strict linearity test.
Source inspected
Full text
Evidence location
Results: Figures 2–3 (illuminance), 4–5 (Speck spectrum), 6 (melanopic EDI), 7 (angular response); Temperature dependence; Discussion limitations.
Curation note
Published 21 July 2026. Results concern Speck v1.0, not v2.0. Melanopic EDI was evaluated only for LYS Button and Speck under LEDs; Actiwatch was excluded because it lacks melanopic outputs. Spectral reconstruction testing applies only to Speck.

Pilehchi-Ha et al. · 2026 · Preprint

Cross-validation of wearable light loggers across electric and natural light conditions: focus on illuminance, melanopic EDI, and CCT ↗

Journal / server
medRxiv
Devices
ActLumus; lido; OcuWEAR
Measurements
Illuminance; Melanopic EDI
Device-specific coverage
ActLumus: Illuminance, Melanopic EDI | lido: Illuminance, Melanopic EDI | OcuWEAR: Illuminance, Melanopic EDI
Setting
Laboratory + field
Evidence type
Reference comparison
Reference
Gigahertz-Optik CSS-45 reference spectroradiometer.
Protocol
Comparison under fluorescent, incandescent and multiple LED sources, plus dynamic daylight exposure.
Reported findings
Performance depended on both the source spectrum and output metric. Illuminance varied less than melanopic EDI and colour temperature. Bias under dim conditions could change exposure-threshold classification.
Limits of interpretation
Preprint. Bias varies with spectrum and metric; not every device was tested in every source condition. No universal accuracy bound or general ranking follows from these comparisons.
Source inspected
Full text
Evidence location
Methods and device-specific illuminance, melanopic EDI and CCT comparisons; CCT reported only for lido and OcuWEAR.
Curation note
CCT performance is indexed only for lido and OcuWEAR; it is not assigned to ActLumus.

Sah et al. · 2026 · Peer reviewed

Five wearable sensors for objective measurement of near work and light exposure ↗

Journal / server
npj Biological Timing and Sleep
Devices
VEET; Clouclip (version not reported); Actiwatch (model not reported); ActLumus; GENEActiv
Measurements
Illuminance
Device-specific coverage
VEET: Illuminance | Clouclip (version not reported): Illuminance | Actiwatch (model not reported): Illuminance | ActLumus: Illuminance | GENEActiv: Illuminance
Setting
Field
Evidence type
Wearable-to-wearable comparison
Reference
Concurrent wearables and participant activity logs; no absolute illuminance reference.
Protocol
Thirty adults wore five sensors for one day; valid light data from 25 participants were compared across illumination categories and with activity logs.
Reported findings
Outdoor-photopic categories agreed well between devices, while low-light categories and activity-log estimates differed.
Limits of interpretation
Authors explicitly assess mutual agreement, not absolute validation. Anatomical position and sensor characteristics differ. Unreported model revisions remain unresolved.
Source inspected
Full text
Evidence location
Abstract; Results: Table 2; Introduction (scope); Methods: wearable sensors.

Ishihara et al. · 2025 · Peer reviewed

Performance of wearable light sensors for measuring photopic and melanopic illuminance under laboratory and free-living conditions ↗

Journal / server
SLEEP
Devices
ActLumus; GENEActiv; ActiGraph wGT3X-BT; LYS Button
Measurements
Illuminance
Device-specific coverage
ActLumus: Illuminance | GENEActiv: Illuminance | ActiGraph wGT3X-BT: Illuminance | LYS Button: Illuminance
Setting
Laboratory + field
Evidence type
Reference comparison
Reference
NIST-calibrated ILT560-A spectrometer; free-living comparison between ActLumus and ActiGraph.
Protocol
Eight units per manufacturer tested under warm/cool LEDs (2–1,000 lx) and daylight (5,000–100,000 lx). Twenty-one adults wore ActLumus and ActiGraph concurrently for one week.
Reported findings
ActLumus had the widest tested response range and lowest between-unit variability. LYS showed larger melanopic errors under warm light. GENEActiv and ActiGraph underestimated illuminance; limited sensitivity and saturation produced large differences in daily exposure estimates.
Limits of interpretation
Two indoor spectra and selected daylight conditions do not cover all lighting environments. The field component compared two wrist devices without a continuously worn reference spectrometer.
Source inspected
Full text
Evidence location
Methods: Laboratory assessment; Results: Figures 2–6 and Free-living comparison (Figure 7).
Curation note
Online November 2025; February 2026 issue. Melanopic testing applies only to ActLumus and LYS. The paper uses melanopic illuminance/lux, not explicitly EDI; indexed here as Other circadian metrics. LYS hardware version is unspecified. Between-unit variability is distinct from repeatability. Additional reported endpoints: Dynamic range, Between-device variability. The LYS name is indexed under LYS Button; these are the same device, as clarified by the curator. The paper does not specify a hardware revision.

Sarkar et al. · 2025 · Peer reviewed

Validation of real-time viewing distance and ambient illumination measurement with two wearable sensors ↗

Journal / server
Ophthalmic and Physiological Optics
Devices
Vivior Mark 3+; Clouclip (second generation)
Measurements
Illuminance
Device-specific coverage
Vivior Mark 3+: Illuminance | Clouclip (second generation): Illuminance
Setting
Laboratory + field
Evidence type
Reference comparison
Reference
Calibrated Konica Minolta CL-200A chroma meter for illumination; ruler for the separate distance assessment.
Protocol
Five units of each model attached to spectacles on a mannequin. Light measurements were repeated across seven indoor/outdoor locations on three days. A separate study tested viewing distance in 13 young adults.
Reported findings
Both devices tracked the luxmeter; individual differences became more variable above roughly 3,500–4,000 lx. Some bright indoor locations exceeded the 1,000-lx outdoor threshold.
Limits of interpretation
The participant component assessed viewing distance rather than light-measurement accuracy during unrestricted wear. The study did not validate melanopic or spectral outputs; sleep mode and spectacle use can affect deployment.
Source inspected
Full text
Evidence location
Methods: Study 1 and device descriptions; Results: Validation of ambient illumination measurements, Figures 6–7; Discussion (repeatability).
Curation note
Published 14 February 2025. Exact tested versions were five Vivior Mark 3+ and five second-generation Clouclip units. Agreement in photopic illuminance should not be generalized to other outputs or hardware generations. Outdoor-threshold discussion is not indexed as classification validation.

Stevenson, Suppiah & Driller · 2025 · Peer reviewed

Research note: The validity and reliability of a novel wearable sensor in measuring light exposure in an indoor and outdoor environment ↗

Journal / server
Lighting Research & Technology
Devices
LYS Button
Measurements
Illuminance
Device-specific coverage
LYS Button: Illuminance
Setting
Laboratory + field
Evidence type
Reference comparison
Reference
Factory-calibrated RS PRO RS-92 digital light meter.
Protocol
Two LYS Buttons were placed side by side with the reference for eight-hour indoor and outdoor recordings. Separate two-hour recordings assessed between-unit reliability.
Reported findings
Buttons read about 25 lx lower indoors and 82 lx higher outdoors on average. Between-unit ICCs were 0.90 indoors and 0.98 outdoors.
Limits of interpretation
Stationary, upward-facing sensors; no free-living wear test. Only illuminance was validated. Removal of outliers and the limited conditions affect interpretation.
Source inspected
Full text
Evidence location
Sections 2.1–2.3; Tables 1–2; Section 3.
Curation note
First published online 3 July 2025; journal issue dated 2026. Do not infer melanopic EDI or CCT validation from the device’s advertised outputs.

McDowell et al. · 2024 · Peer reviewed

Beyond Lux: methods for species and photoreceptor-specific quantification of ambient light for mammals ↗

Journal / server
BMC Biology
Devices
SpectraWear
Measurements
Melanopic EDI
Device-specific coverage
SpectraWear: Melanopic EDI
Setting
Laboratory
Evidence type
Calibration study
Reference
Calibrated SpectroCal spectroradiometer; species-specific photoreceptor weighting functions.
Protocol
Ten-channel readings were fitted to reference measurements from 13 spectra, then tested at a wider range of irradiances. Performance was assessed for 12 domestic mammal species and humans.
Reported findings
Melanopic and rhodopic estimates performed better than short-wavelength cone estimates; limited UV sensitivity constrained some species-specific quantities.
Limits of interpretation
Bench calibration of wearable hardware, not an on-body validation. Accuracy depends on the spectra and species-specific response being estimated.
Source inspected
Full text
Evidence location
Figure 2; Methods: Light sensor calibration and validation.

Mohammadian et al. · 2024 · Peer reviewed

A Wrist-Worn Internet of Things Sensor Node for Wearable Equivalent Daylight Illuminance Monitoring ↗

Journal / server
IEEE Internet of Things Journal
Devices
SpectraWear
Measurements
Angular response; Melanopic EDI
Device-specific coverage
SpectraWear: Melanopic EDI, Angular response
Setting
Laboratory + field
Evidence type
Characterisation + placement
Reference
SpectroCAL MKII spectroradiometer and calibrated custom spectral source.
Protocol
Thirteen ten-channel units were calibrated and tested across spectral/intensity conditions, with additional angular-response and body-location experiments.
Reported findings
Mean absolute errors in α-opic EDI were below 0.07 log lx; between-unit correlations were at least 0.99 under the reported conditions.
Limits of interpretation
Laboratory calibration and limited wear demonstrations do not establish equal performance under every real-world spectrum or placement.
Source inspected
Full text
Evidence location
Sections II-D, III-B and IV: calibration, EDI accuracy, directional response and wearing position.
Curation note
SpectraWear is the name used for this research platform in associated publications; the engineering paper describes a wrist-worn sensor node.

Stampfli et al. · 2023 · Peer reviewed

The Light-Dosimeter: A new device to help advance research on the non-visual responses to light ↗

Journal / server
Lighting Research & Technology
Devices
lido
Measurements
Angular response; Illuminance
Device-specific coverage
lido: Illuminance, Angular response
Setting
Laboratory + field
Evidence type
Characterisation
Reference
JETI specbos 1201 spectroradiometer; Ocean Insight STS-VIS for a real-world demonstration.
Protocol
Integrating-sphere calibration; tests under incandescent, LED, fluorescent and daylight sources; illuminance/CCT and angular-response characterization; near-corneal melanopic irradiance compared with a portable spectroradiometer.
Reported findings
The development study reports satisfactory agreement with commercial reference equipment and demonstrates coordinated near-corneal light recording during a field experiment.
Limits of interpretation
Developer-led characterization and a limited demonstration; the reported results do not establish performance under every spectrum, wearing position or field condition.
Source inspected
Full text
Evidence location
Sections 2.5 and 3.1; Figures 8–9 (illuminance/CCT/angular tests); Section 3.3 and Figures 10–11 (melanopic irradiance comparison).
Curation note
Published online 13 February 2023. The article describes lido and its calibration workflow. Its field demonstration concerns melanopic irradiance, which should not be relabeled melanopic EDI.

Dhakal et al. · 2022 · Peer reviewed

Development and validation of a ‘MyLyt’ wearable light tracking device ↗

Journal / server
Ophthalmic and Physiological Optics
Devices
MyLyt
Measurements
Illuminance
Device-specific coverage
MyLyt: Illuminance
Setting
Laboratory + field
Evidence type
Reference comparison
Reference
Factory-calibrated Sinometer LX1330B lux meter; activity diaries for indoor/outdoor classification.
Protocol
Four trackers were tested in a controlled chamber and indoor/outdoor settings. A field phase included 21 adults and eight children.
Reported findings
Repeated and between-unit measurements were consistent. Reference agreement varied by setting; diary-based indoor/outdoor classification had high sensitivity and specificity in this sample.
Limits of interpretation
Classification uses self-reported location. Illuminance agreement is not proof of accuracy for spectra or melanopic quantities.
Source inspected
Full text
Evidence location
Methods: Phase 1/2 validation; Results: Figures 3–5 and Tables 2–4.
Curation note
Online publication 22 October 2022; issue year 2023.

Bhandari, Mirhajianmoghadam & Ostrin · 2021 · Peer reviewed

Wearable Sensors for Measurement of Viewing Behavior, Light Exposure, and Sleep ↗

Journal / server
Sensors
Devices
Clouclip (version not reported); Actiwatch Spectrum Plus
Measurements
Illuminance
Device-specific coverage
Clouclip (version not reported): Illuminance | Actiwatch Spectrum Plus: Illuminance
Setting
Field
Evidence type
Wearable-to-wearable comparison
Reference
Concurrent spectacle-mounted Clouclip, wrist Actiwatch Spectrum Plus, daily logs and questionnaire.
Protocol
Twenty-five adults wore both devices for one week. Illuminance and time above the outdoor threshold were compared with each other and self-reports.
Reported findings
Wrist Actiwatch illuminance was systematically lower than Clouclip. Questionnaire estimates of outdoor time exceeded both device estimates.
Limits of interpretation
Placement and device are confounded. This study evaluates agreement and behaviour estimates, not absolute sensor accuracy against a photometer.
Source inspected
Full text
Evidence location
Sections 2.2–2.3 and light-exposure results.

Falck et al. · 2021 · Peer reviewed

Shining the Light on the MotionWatch8 Light Sensor for Sleep and Aging Research: What Can We Measure and What Are We Missing? ↗

Journal / server
Journal of Alzheimer's Disease Reports
Devices
MotionWatch 8
Measurements
Illuminance
Device-specific coverage
MotionWatch 8: Illuminance
Setting
Laboratory + field
Evidence type
Reference comparison
Reference
Extech LT40 LED light meter.
Protocol
Seventeen everyday scenarios were sampled for five minutes each, including tests with and without sleeves. Thresholds classified light/dark, electrical/daylight and bright-light therapy.
Reported findings
The watch distinguished some lighting classes but had poor absolute agreement and did not reliably identify bright-light therapy. Sleeves commonly reduced readings.
Limits of interpretation
Scenario-specific thresholds are not universal. A small controlled wear demonstration cannot establish general free-living accuracy.
Source inspected
Full text
Evidence location
Methods; Table 3; Figures 1–4.

Howell et al. · 2021 · Peer reviewed

Reliability and validity of the Actiwatch and Clouclip for measuring illumination in real-world conditions ↗

Journal / server
Ophthalmic and Physiological Optics
Devices
Actiwatch 2; Clouclip (second generation)
Measurements
Illuminance
Device-specific coverage
Actiwatch 2: Illuminance | Clouclip (second generation): Illuminance
Setting
Field
Evidence type
Reference comparison
Reference
Manufacturer-calibrated Hagner S2 universal photometer.
Protocol
Devices on a skeleton were compared with a photometer at matched sensor positions in nine indoor/outdoor settings. Five Clouclip M2 units were also compared concurrently.
Reported findings
Both devices underestimated illuminance despite high correlations. Clouclip more closely reproduced the reference in the tested range; its between-unit illuminance ICC was 0.85.
Limits of interpretation
Device-reference trials were separate and covered different ranges. Indoor locations can exceed 1,000 lx; an illuminance category is not necessarily an outdoor location.
Source inspected
Full text
Evidence location
Methods: Devices employed and Validity; Results: Tables 2–4, Figures 3–5.

Mohamed et al. · 2021 · Peer reviewed

Wearable light spectral sensor optimized for measuring daily α-opic light exposure ↗

Journal / server
Optics Express
Devices
Mohamed et al. spectrophotometer
Measurements
Angular response; Illuminance; Melanopic EDI
Device-specific coverage
Mohamed et al. spectrophotometer: Illuminance, Melanopic EDI, Angular response
Setting
Laboratory
Evidence type
Characterisation
Reference
Konica Minolta CL-500A calibrated illuminance spectrophotometer.
Protocol
A pendant/clip spectrophotometer covering 380–780 nm was developed and tested with common light sources; corrections addressed directionality, dark noise, saturation, nonlinearity, stray light and spectral response.
Reported findings
After correction, the reported α-opic EDI errors were below 7% for the four tested source types. Optical modification improved angular response; remaining spectral errors differed by source.
Limits of interpretation
Bench testing of a prototype with four source types does not establish accuracy for every spectrum or wearing condition. No equivalence to a later branded device is inferred.
Source inspected
Full text
Evidence location
Sections 2.2 and 3; Table 1 (angular response), Table 2 and Figure 8 (source comparisons).

Nagra et al. · 2021 · Peer reviewed

Intra- and Inter-Model Variability of Light Detection Using a Commercially Available Light Sensor ↗

Journal / server
Journal of Medical Systems
Devices
Actiwatch Spectrum Pro
Measurements
Illuminance
Device-specific coverage
Actiwatch Spectrum Pro: Illuminance
Setting
Laboratory
Evidence type
Repeatability study
Reference
Controlled Gretag Macbeth Judge II lightbox; comparison among four watches and two sessions.
Protocol
RGB and white outputs were recorded under simulated daylight D65, illuminant A and cool-white fluorescent light.
Reported findings
Significant between-watch differences occurred under all three illuminants; repeated measurements also differed for most watch/channel combinations.
Limits of interpretation
Four units. This establishes variability, not traceable absolute illuminance accuracy. Despite the title, the tested watches are all Spectrum Pro.
Source inspected
Full text
Evidence location
Abstract; Methods: illumination conditions and procedure; Results.

Webler, Chinazzo & Andersen · 2021 · Peer reviewed

Towards a wearable sensor for spectrally-resolved personal light monitoring ↗

Journal / server
Journal of Physics: Conference Series
Devices
Spectrace
Measurements
Angular response; Illuminance
Device-specific coverage
Spectrace: Illuminance, Angular response
Setting
Laboratory
Evidence type
Characterisation
Reference
Reference spectra; LMT Pocket-Lux 2 for angular-response measurements.
Protocol
Prototype tests examined spectral reconstruction, angular response and intensity linearity; a separate survey assessed wearability.
Reported findings
Measured angular mismatch was 2.07%. Spectral reconstruction and intensity response depended on the tested signal and source conditions.
Limits of interpretation
Prototype and conference paper. Spectral recovery demonstrations do not establish arbitrary-spectrum reconstruction or a separately validated melanopic EDI output.
Source inspected
Full text
Evidence location
Sections 2.1 and 3.1.1–3.1.3; Figures 1–4.
Curation note
Full conference proceedings paper (CISBAT 2021), not an abstract.

Wen et al. · 2021 · Peer reviewed

The Clouclip, a wearable device for measuring near-work and outdoor time: validation and comparison of objective measures with questionnaire estimates ↗

Journal / server
Acta Ophthalmologica
Devices
Clouclip (first generation)
Measurements
Illuminance
Device-specific coverage
Clouclip (first generation): Illuminance
Setting
Laboratory + field
Evidence type
Reference comparison
Reference
Konica Minolta T-10 illuminance meter.
Protocol
Fifteen first-generation units were tested in 28 light environments spanning 50–38,000 lx, with repeated measurements. A separate participant study compared device records with questionnaires.
Reported findings
Controlled light tests reported a maximum relative error of 2.23% and high within- and between-unit consistency.
Limits of interpretation
Questionnaires are not a traceable illuminance reference. Results apply to the first-generation units and tested environments.
Source inspected
Full text
Evidence location
Methods: Validation of Clouclip; light-intensity validation results.

Bhandari & Ostrin · 2020 · Peer reviewed

Validation of the Clouclip and utility in measuring viewing distance in adults ↗

Journal / server
Ophthalmic and Physiological Optics
Devices
Clouclip (second generation)
Measurements
Illuminance
Device-specific coverage
Clouclip (second generation): Illuminance
Setting
Laboratory + field
Evidence type
Reference comparison
Reference
Dr. Meter LX1330B digital lux meter.
Protocol
Clouclip and reference sensors were aligned in indoor and outdoor locations, including shade and direct sunlight. The paper separately tested viewing distance.
Reported findings
Illuminance was strongly correlated with the reference, but disagreement grew at high levels, particularly above 20,000 lx.
Limits of interpretation
Distance performance does not establish light accuracy. Staged measurements do not reproduce continuous on-body occlusion.
Source inspected
Full text
Evidence location
Methods: Ambient illumination; Results: Figure 7.

Joyce, Zele, Feigl & Adhikari · 2020 · Peer reviewed

The accuracy of artificial and natural light measurements by actigraphs ↗

Journal / server
Journal of Sleep Research
Devices
GENEActiv Original; Actiwatch 2
Measurements
Illuminance
Device-specific coverage
GENEActiv Original: Illuminance | Actiwatch 2: Illuminance
Setting
Laboratory + field
Evidence type
Reference comparison
Reference
Calibrated laboratory-standard photometer.
Protocol
Compared device illuminance with a photometer under white LED light and natural sunlight; also tested neutral-density filters to extend measurement range.
Reported findings
At about 20,000 lux LED light, GENEActiv and Actiwatch 2 recorded about 50% and 25% of reference illuminance, respectively. At about 30,000 lux sunlight, GENEActiv saturated and Actiwatch 2 recorded about 46%.
Limits of interpretation
Absolute readings required correction under tested conditions. Temporal tracking does not imply absolute accuracy; reported correction factors should not be assumed universal across spectra or device versions.
Source inspected
Abstract
Evidence location
Abstract: photometer comparison, LED/sunlight under-reading, saturation and neutral-density filters.
Curation note
Journal of Sleep Research 29(5), e12963. Online publication December 2019; journal issue October 2020. Primary publisher abstract also verified at https://doi.org/10.1111/jsr.12963 . Additional reported endpoints: Linearity, Dynamic range.

Stone, McGlashan, Facer-Childs, Cain & Phillips · 2020 · Peer reviewed

Accuracy of the GENEActiv Device for Measuring Light Exposure in Sleep and Circadian Research ↗

Journal / server
Clocks & Sleep
Devices
GENEActiv Original
Measurements
Illuminance
Device-specific coverage
GENEActiv Original: Illuminance
Setting
Laboratory + field
Evidence type
Characterisation
Reference
J17 Luma Color illuminance meter; MK350N spectrometer for spectral measurements.
Protocol
Ten units tested under fluorescent and LED illumination, darkness, overcast outdoor daylight, narrowband blue/green/red LEDs and an infrared camera illuminator.
Reported findings
Outputs tracked illuminance but generally underestimated it, particularly below 100 lux. Accuracy depended on spectrum: green light was under-reported, red light over-reported, and infrared affected the measurements.
Limits of interpretation
Low-light accuracy varied by source. Recording relative light patterns or distinguishing indoor/outdoor conditions does not establish accurate absolute exposure in dim environments.
Source inspected
Full text
Evidence location
§2.1–2.4: devices, stimuli and protocol; Table 2 and Results: intensity accuracy, spectral/infrared effects and inter-device reliability.
Curation note
Clocks & Sleep 2(2), 143–152. Inter-device reliability is reported separately from repeatability; findings apply to tested hardware/software. Additional reported endpoints: Low-light response, Inter-device reliability.

Argüelles-Prieto et al. · 2019 · Peer reviewed

Determining Light Intensity, Timing and Type of Visible and Circadian Light From an Ambulatory Circadian Monitoring Device ↗

Journal / server
Frontiers in Physiology
Devices
Kronowise
Measurements
Illuminance
Device-specific coverage
Kronowise: Illuminance
Setting
Laboratory
Evidence type
Calibration study
Reference
Ocean Optics spectroradiometer with CC-3 cosine corrector; CIE S 026 calculations from reference spectra.
Protocol
Commercial lamps and sunlight were compared with three-channel Kronowise readings; separate calibration relationships were developed for natural and two artificial-light classes.
Reported findings
Source-specific transformations improved correspondence with reference visible and circadian-light estimates relative to raw outputs.
Limits of interpretation
Results depend on the source classifier and fitted calibration. The paper’s circadian channel is not automatically interchangeable with every modern melanopic EDI implementation.
Source inspected
Full text
Evidence location
Methods: calibration; Results: light-source classification and calibrated visible/circadian measurements.

Ostrin · 2017 · Peer reviewed

Objectively Measured Light Exposure in Emmetropic and Myopic Adults ↗

Journal / server
Optometry and Vision Science
Devices
Actiwatch Spectrum
Measurements
Illuminance
Device-specific coverage
Actiwatch Spectrum: Illuminance
Setting
Laboratory + field
Evidence type
Calibration study
Reference
Lux meter and UV sensor; models unresolved in the inspected abstract.
Protocol
The paper reports indoor/outdoor device calibration in addition to 14-day recordings in 55 adults and comparisons with activity questionnaires.
Reported findings
An original calibration component is reported alongside the exposure study; numerical sensor agreement has not been extracted from the accessible abstract.
Limits of interpretation
Abstract-level calibration record. The observational refractive-error comparisons do not themselves validate the sensor; quantitative accuracy requires full-text extraction.
Source inspected
Abstract
Evidence location
Publisher abstract, Methods: calibration against a lux meter and UV sensor.

Price, Lyachev & Khazova · 2017 · Peer reviewed

Optical performance characterization of light-logging actigraphy dosimeters ↗

Journal / server
Journal of the Optical Society of America A
Devices
MotionWatch 8; ActTrust; GENEActiv Original; Actiwatch 2
Measurements
Angular response
Device-specific coverage
MotionWatch 8: Angular response | ActTrust: Angular response | GENEActiv Original: Angular response | Actiwatch 2: Angular response
Setting
Laboratory
Evidence type
Characterisation
Reference
Photopic and photoreceptor sensitivity functions, cosine response and reference values for dynamic characterization.
Protocol
New optical tests and existing evidence were combined. This record indexes four complete-protocol models with individually identifiable spectral and angular results: MotionWatch 8, ActTrust, GENEActiv Original and Actiwatch 2.
Reported findings
Optical characterization covers directional and spectral sensitivity, linearity, dynamic range and resolution, with a proposed assessment protocol. Results are model- and channel-specific.
Limits of interpretation
Only abstract and publisher tables were inspected. Other models discussed in the paper are omitted here to avoid counting reused evidence or assigning combined model results to individual variants.
Source inspected
Abstract
Evidence location
Table 1: complete-protocol models; Table 2: spectral mismatch; Table 3: cosine-response error; Table 4: dynamic performance.
Curation note
Abstract and Tables 1–4 inspected. Indexed coverage restricted to individually identifiable spectral and angular tests. Additional reported endpoints: Linearity, Dynamic range, Resolution.

Markvart et al. · 2015 · Peer reviewed

Comparison and Correction of the Light Sensor Output from 48 Wearable Light Exposure Devices by Using a Side-by-Side Field Calibration Method ↗

Journal / server
LEUKOS
Devices
Actiwatch Spectrum
Measurements
Illuminance
Device-specific coverage
Actiwatch Spectrum: Illuminance
Setting
Laboratory
Evidence type
Between-unit calibration
Reference
Side-by-side comparison among 48 Actiwatch Spectrum units.
Protocol
RGB and white outputs were compared under different light sources to develop a field-calibration procedure.
Reported findings
The study documents between-unit response variation and proposes corrections based on concurrent measurements.
Limits of interpretation
Agreement after field correction does not by itself establish traceable absolute accuracy. Detailed correction coefficients require the full paper.
Source inspected
Abstract
Evidence location
Author-deposited abstract: study aim, device model and protocol.

Figueiro, Hamner, Bierman & Rea · 2013 · Peer reviewed

Comparisons of three practical field devices used to measure personal light exposures and activity levels ↗

Journal / server
Lighting Research & Technology
Devices
Daysimeter-S; Daysimeter-D; Actiwatch Spectrum
Measurements
Angular response; Illuminance
Device-specific coverage
Daysimeter-S: Illuminance, Angular response | Daysimeter-D: Illuminance, Angular response | Actiwatch Spectrum: Illuminance, Angular response
Setting
Laboratory + field
Evidence type
Characterisation
Reference
Photopic V(λ), cosine response and calibrated near-eye Daysimeter measurements for placement comparisons.
Protocol
Optical characterization and field comparisons: 12 adults over 65 wore Daysimeters at four body locations and a wrist Actiwatch; five days analyzed.
Reported findings
Daysimeters performed better photometrically than Actiwatch Spectrum. Wrist measurements differed from near-cornea exposure.
Limits of interpretation
Neither device qualified as a laboratory-grade photometer. Field evidence is from older adults; circadian light and stimulus are model-specific quantities, not CIE melanopic EDI.
Source inspected
Full text
Evidence location
§2.2.1, Figures 3–5: optical performance; §3.2–3.3, Figure 6: Daysimeter placement; Figure 7: wrist comparison.
Curation note
Five of seven days analyzed. Placement comparisons used Daysimeters; Actiwatch remained at the wrist.

Price, Khazova & O’Hagan · 2012 · Peer reviewed

Performance assessment of commercial circadian personal exposure devices ↗

Journal / server
Lighting Research & Technology
Devices
Actiwatch Spectrum
Measurements
Angular response
Device-specific coverage
Actiwatch Spectrum: Angular response
Setting
Laboratory
Evidence type
Characterisation
Reference
Optical characterization; abstract does not identify all reference instruments.
Protocol
Sixteen Actiwatch Spectrum units were evaluated for spectral response, directional response and dynamic range.
Reported findings
The paper reports optical performance and proposes calibration, deployment and analysis techniques for circadian studies.
Limits of interpretation
Only the abstract was inspected for this record. It supports the scope of testing, but is insufficient for a quantitative accuracy judgment.
Source inspected
Abstract
Evidence location
Abstract: 16 units; spectral response, directional response and dynamic range.
Curation note
Metadata and abstract verified at the authors’ institution: https://researchportal.ukhsa.gov.uk/en/publications/performance-assessment-of-commercial-circadian-personal-exposure–2/ . Lighting Research & Technology 44(1), 17–26. Additional reported endpoints: Dynamic range.

Bierman, Klein & Rea · 2005 · Peer reviewed

The Daysimeter: a device for measuring optical radiation as a stimulus for the human circadian system ↗

Journal / server
Measurement Science and Technology
Devices
Daysimeter (2005 prototype)
Measurements
Illuminance
Device-specific coverage
Daysimeter (2005 prototype): Illuminance
Setting
Laboratory
Evidence type
Characterisation
Reference
Photo Research LRS 450 Light Standard; spectral matching against the photopic response.
Protocol
Two prototypes were checked for spectral response. Linearity was tested against an integrating-sphere source with an approximately illuminant-A spectrum.
Reported findings
Photopic spectral-mismatch values were 3.8% and 5.4%. The tested response departed from linearity by a few percent across roughly 3.5 decades of irradiance.
Limits of interpretation
Partial full-text extraction from the indexed author PDF. The instrument’s higher advertised range was not tested. This record does not establish modern melanopic EDI accuracy.
Source inspected
Partial full text
Evidence location
Author PDF, Section 3.1.3: Radiation measurement verification; Figure 3.
Curation note
Primary passage accessible through indexed PDF text; direct download failed. Additional endpoints await complete full-text inspection.